What is NABL ISO 15189 accreditation?
NABL (National Accreditation Board for Testing and Calibration Laboratories) accredits medical laboratories in India against ISO 15189, the international standard for quality and competence in medical labs. It covers management (documents, records, complaints, reviews) and technical areas (staff competence, equipment, pre-examination, examination, post-examination and reporting). Accreditation is voluntary but valued by doctors, insurers and corporate clients.
Which ISO 15189 requirements can software support?
| Area | What assessors look for | How an LIS helps |
|---|---|---|
| Sample identification | Unique, unambiguous labelling | Barcode labels printed at collection |
| Traceability | Who did what, and when | Time-stamped entries linked to user logins |
| Reference intervals | Defined, appropriate ranges | Age- and gender-wise ranges stored in the test master |
| Result review | Authorised release | Pathologist approval with digital signature |
| Report content | Patient ID, sample type, dates, units, ranges, signatory | Report templates with all fields filled automatically |
| Turnaround time | Monitored TAT | Registration, entry and approval times recorded |
| Record retention | Retrievable records | Patient history searchable by patient, date or bill |
| Access control | Confidentiality | Role-based permissions |
What must a lab still do outside the software?
- Write and control the quality manual and SOPs.
- Run internal quality control and take part in external quality assessment (EQAS/PT).
- Calibrate and maintain equipment and keep logs.
- Train staff and record competence.
- Run internal audits and management reviews.
- Validate methods and verify reference intervals.
Software keeps patient-side records clean; the quality system is still the lab's work.
Which QLab features are useful for an accreditation-ready lab?
- Barcode sample tracking from collection to report.
- Result entry with reference ranges, automatic flags and previous values beside each result.
- Pathologist approval with digital signature before release.
- Reports with QR code so any reader can verify authenticity.
- Roles and permissions for reception, technicians, pathologists and accounts.
- ASTM interfacing to cut transcription errors.
QLab itself is a software product; accreditation is granted to labs, not to software.
How should a lab prepare its software for an assessment?
- Check every test in the master has the correct unit, method and reference range.
- Make sure each user has their own login – no shared passwords.
- Confirm the report template shows sample type, collection and report times, and the signatory.
- Pull a turnaround-time sample for the last month.
- Show how a report can be traced back to its sample, technician and approver.
What gaps do assessors commonly find in lab records?
- Shared logins, so no one can tell who entered or approved a result.
- Reference ranges on reports that do not match the lab's documented ranges.
- Reports without sample collection time or sample type.
- Edited results with no record of the original value or the reason.
- Turnaround time claimed but never measured.
- Hand-written sample labels that do not match the request form.
A properly configured LIS fixes each of these at the source instead of tidying files before the visit.
How does a lab move from paper to an accreditation-ready LIS?
- Clean the test master – one entry per test with method, unit, sample type and verified ranges (test master).
- Set up users and roles – named logins and permissions for every staff member (roles).
- Turn on barcodes at collection.
- Configure approval so only authorised signatories release reports.
- Design the report to include every element ISO 15189 expects.
- Interface analysers where possible.
- Review monthly – TAT, edited results and rejected samples.
Does this help labs that are not seeking NABL?
Yes. The same traceability that assessors want also protects a lab when a doctor or patient questions a result. Showing who collected the sample, when it was processed, the raw value and who approved it settles most disputes in minutes, and makes a later NABL application far easier. Start with QLab and grow into accreditation.
Frequently asked questions
Is lab software required for NABL accreditation?
Not strictly, but keeping ISO 15189 records manually is hard. Most accredited labs use an LIS for traceability and reporting.
Is QLab NABL certified?
NABL accredits laboratories, not software. QLab provides the traceability, audit trail and report features that accredited labs rely on.
Does an LIS help with turnaround time monitoring?
Yes. Registration, result entry and approval times are recorded, so TAT can be reviewed per test or department.
Can reports carry a QR code for verification?
Yes. QLab reports include a QR code and barcode so recipients can check the report is genuine.